Huawei H12-461 VCE, HCIE-Data Center Facility Design Dumps, H12-461 PDF, H12-461 Dumps, HCIE-Data Center Facility Design VCE, Huawei HCIE-Data Center Facility Design PDFGetting knowledge of the Huawei H12-461 exam structure and question format is vital in preparing for the Huawei Certified ICT Expert-Data Center Facility Design certification exam. Our Huawei HCIE-Data Center Facility Design sample questions offer you information regarding the question types and level of difficulty you will face in the real exam. The benefit of using these Huawei H12-461 sample questions is that you will get to check your preparation level or enhance your knowledge by learning the unknown questions. You will also get a clear idea of the exam environment and exam pattern you will face in the actual exam with the Huawei Certified ICT Expert-Data Center Facility Design Sample Practice Test. Therefore, solve the Huawei HCIE-Data Center Facility Design sample questions to stay one step forward in grabbing the Huawei Certified ICT Expert-Data Center Facility Design credential.

These Huawei H12-461 sample questions are simple and basic questions similar to the actual Huawei HCIE-Data Center Facility Design questions. If you want to evaluate your preparation level, we suggest taking our Huawei Certified ICT Expert-Data Center Facility Design Premium Practice Test. You might face difficulties while solving the real-exam-like questions. But, you can work hard and build your confidence on the syllabus topics through unlimited practice attempts.

Huawei H12-461 Sample Questions:

01. In the data center evaluation model, which metric is most indicative of a data center's energy efficiency?
a)
Uptime
b) PUE (Power Usage Effectiveness)
c) MTBF (Mean Time Between Failures)
d) Latency
 
02. Considerations for selecting chilled water pumps include which of the following?
(Choose Three)
a) Pump efficiency
b) Ability to match the data center's interior design
c) Compatibility with the chiller capacity
d) Durability and reliability
e) Operational noise levels
 
03. Why is it important to accurately calculate the load when selecting chilled water units?
a)
To minimize operational costs
b) To ensure color uniformity
c) To maximize noise output
d) To comply with local fashion trends
 
04. During the selection of a chilled water system, it is crucial to consider the __________ of the components.
a)
color
b) brand
c) reliability
d) shape
 
05. What are important considerations when selecting a cooling tower for a data center?

(Choose Two)
a) Color of the tower
b) Thermal efficiency and capacity
c) Integration with other cooling infrastructure
d) Noise generation

 
06. When evaluating potential sites for a data center, which factor is most important for ensuring data security?

a) Proximity to power sources
b) Natural disaster risk assessment
c) Availability of high-speed internet
d) Local regulatory compliance

 
07. How should a data center's cooling load be calculated?
(Choose Two)
a) Based on the maximum expected ambient temperature
b) Based on the total floor area of the data center
c) Based on the heat output of the IT equipment
d) Based on the type of flooring used
 
08. The cooling load estimation should be based on __________ data to ensure accuracy.
a)
theoretical
b) estimated
c) actual measured
d) randomly selected
 
09. What factors should be considered when selecting chilled water units for a data center?
(Choose Three)
a) Brand popularity
b) Capacity and efficiency
c) Compatibility with existing systems
d) Noise levels
e) Color of the units
 
10. Which of the following best describes the relationship between DCIM systems and IT Service Management (ITSM) systems?
a)
DCIM systems operate independently of ITSM systems with no overlap
b) DCIM systems are a component of ITSM systems
c) DCIM systems can integrate with ITSM systems to enhance overall IT operations and infrastructure management
d) ITSM systems are generally phased out when DCIM is introduced

Answers:

Question: 01
Answer: b
Question: 02
Answer: a, c, d
Question: 03
Answer: a
Question: 04
Answer: c
Question: 05
Answer: b, c
Question: 06
Answer: d
Question: 07
Answer: a, c
Question: 08
Answer: c
Question: 09
Answer: b, c, d
Question: 10
Answer: c